Syringe Seal Positive Pressure Tester ISO 7886

Syringe Seal Positive Pressure Tester ISO 7886

The Syringe Seal Positive Pressure Tester is a precision testing instrument designed to evaluate the sealing performance of medical syringes under specified positive pressure conditions. By applying controlled axial pressure and lateral force to simulate actual syringe use, the tester accurately determines whether syringe sealing performance meets relevant quality requirements. The instrument features touch screen operation, automatic timing, real-time parameter display, and built-in printing capability, making it suitable for medical device manufacturers, quality control laboratories, and research institutions.

Application

Syringe seal positive pressure tester is suitable for measuring the closeness of medical syringes. It can accurately determine whether the syringe sealing performance meets the specified requirements.

Syringes are widely used in medicine industry. Its quality is closely related to our health and safety. Syringe positive pressure tester introduces new technology design, 5.7-inch (120 × 90) single-color LCD touch screen display. The nominal capacity of the syringe, lateral force used for leak test and the axial pressure are selected by the keyboard, and lateral force, axial pressure, duration action time on the mandrel are displayed during testing and test result can be printed by the on-board printer.

Standards

(1) ISO 7886-1 — Sterile Hypodermic Syringes for Single Use — Part 1: Syringes for Manual Use

(2) ISO 7886-2 — Sterile Hypodermic Syringes for Single Use — Part 2: Syringes for Use with Power-Driven Syringe Pumps

(3) ISO 7886-3 — Sterile Hypodermic Syringes for Single Use — Part 3: Auto-Disable Syringes

(4) ISO 7886-4 — Sterile Hypodermic Syringes for Single Use — Part 4: Syringes with Reuse Prevention Feature

(5) GB/T 15810 — Disposable Sterile Hypodermic Syringes for Single Use

(6) GB/T 1962 Series — Test Methods for Connectors and Syringes Used in Medical Applications

Technical Parameters

Lateral force: 0.25N ~ 3N, error is not greater than ± 5%

Axial pressure: 100Kpa ~ 400Kpa, error is not greater than ± 5%

Nominal capacity: 1ml ~ 60ml, any choice

Test time: 30S ± 5S, the error is not greater than ± 1S

Net weight: 12kg

Overall dimensions: 485mm × 345mm × 300mm

Part list

1. Host 1 set

2. Printing paper 1 roll

3. Fixture 1set

4. Weight 1 set

5. Operating Instruction

Features

High-quality material structure, better anti-corrosion performance, long service life.

Design layout is reasonable, beautiful appearance and small size.

Key operation, keyboard selection, automatic timing, single color LCD touch screen. Operation is easy.

Instrument is of high stability, lateral force error is not greater than ± 0.5%, test time error is not greater than ± 1s.

Inbuilt printer prints test results.

FAQ

(1) What performance does this tester evaluate for medical syringes?

The instrument evaluates syringe sealing reliability by applying specified axial pressure and lateral force. It helps identify leakage risks caused by poor sealing, assembly defects, or material problems during syringe production and quality verification.

(2) What syringe sizes can be tested with this equipment?

The tester supports syringes with nominal capacities from 1ml to 60ml. Before testing, users should confirm the required fixture configuration and test conditions according to the syringe type and applicable standard requirements.

(3) Why is positive pressure testing important for syringe quality control?

Positive pressure testing simulates pressure conditions that may occur during syringe use. It helps manufacturers verify sealing performance and reduce potential failures caused by leakage, ensuring safer medical device applications.

(4) How can laboratories ensure test result reliability?

Reliable results depend on correct sample installation, suitable test parameters, and regular instrument calibration. The tester is designed with controlled force and pressure systems to reduce operational errors and improve repeatability.

(5) How should a laboratory select a suitable syringe sealing tester?

Selection should consider syringe capacity range, required testing standards, pressure range, data management needs, and production inspection requirements. Each QINSUN testing machine undergoes factory inspection and performance verification before delivery to ensure measurement accuracy and reliable test data. For suitable testing solutions, please contact QINSUN engineers for professional guidance.


Note:QINSUN is very in place for textile testing and quality control,we have our own textile testing lab. Our textile testing equipment and testing methods are in the leading position in the industry. We have passed the textile testing certification and iso textile testing standards issued by a number of testing,We can provide textile testing equipment pdf manual. Sufficient inventory, big discounts, limited time promotion, Order now!

Leave Message Get Price